10




Our range of coaxial wiring offers solutions for varying requirements for loss, thermal conductivity and frequency within both non magnetic environments and magnetic fields. We offer a size of UT47 as standard but can also offer UT85 upon request.


|
Material |
Stainless Steel Flexible |
Berylium Copper/Silver Plated Berylium Copper | Cupro-Nickel/Silver Plated Cupro-Nickel | Stainless Steel/Silver Plated Stainless Steel | Beryllium Copper | Cupro-Nickel | Stainless Steel |
|
Size |
UT47 |
||||||
|
Attenuation @ 5Ghz @ 300K |
40.526 db/m |
3.1 db/m | 4.7 db/m | 5.8 db/m | 5.1 db/m | 12 db/m | 16.6 db/m |
|
Attenuation @ 5Ghz @4K |
|
1.1 db/m | 2.3 db/m | 2.6 db/m | 4.0 db/m | 9.1 db/m | 10.4 db/m |
|
Thermal Conductivity @ 4K |
|
177 x10-6 W.cm/k | 104 x10-6 W.cm/k | 99.5 x10-6 W.cm/k | 91 x10-6 W.cm/k | 17.4 x10-6 W.cm/k | 13.2 x10-6 W.cm/k |
| Magnetic | No | Yes | Yes | No | Yes | Yes | |
| Connectors | SMA both ends | Hermetically sealed SMAat room temperature and SMPM at the sample. | |||||